  electrical data primary nominal primary current type r.m.s. current measuring range 4) i pn (a) i p (a) 200 600 hat 200-s 400 1200 hat 400-s 500 1500 hat 500-s 600 1800 hat 600-s 750 2250 hat 750-s 800 2400 hat 800-s 1000 3000 hat 1000-s 1200 3000 hat 1200-s 1500 3000 hat 1500-s v c supply voltage ( 5 %) 4) 15 v i c current consumption 15 ma r is isolation resistance @ 500 vdc > 1000 m w v out output voltage @ i pn , r l = 10 k w , t a = 25c 4 v r out output internal resistance 100 w r l load resistance > 10 k w accuracy-dynamic performance data x accuracy @ i pn , t a = 25c (without offset) < 1 % of i pn e l linearity error 1) (0 .. i pn ) < 1 % of i pn v oe electrical offset voltage, t a = 25c < 20 mv v oh hysteresis offset voltage @ i p = 0; after an excursion of 1 x i pn < 10 mv v ot thermal drift of v oe < 1 mv/k tc e g thermal drift of the gain (% of reading) < 0.1 %/k t r response time @ 90% of i p < 5 s f frequency bandwidth 2) (- 3 db) dc .. 25 khz general data t a ambient operating temperature - 10 .. + 80 c t s ambient storage temperature hat 200-s, hat 500..1500-s - 15 .. + 85 c hat 400-s - 25 .. + 85 c m mass 300 g ul94 classification v0 current transducer hat 200..1500- s for the electronic measurement of currents: dc, ac, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). i pn = 200..1500 a v out = 4 v features hall effect measuring principle galvanic isolation between primary and secondary circuit isolation voltage 3000 v low power consumption extended measuring range ( 3 x i pn ) insulated plastic case recognized according to ul 94-v0 advantages easy mounting small size and space saving only one design for wide current ratings range high immunity to external interference. applications dc motor drives switched mode power supplies (smps) ac variable speed drives uninterruptible power supplies (ups) battery supplied applications power supplies for welding applications notes : 1) linearity data exclude the electrical offset. 2) please refer to derating curves in the technical file to avoid excessive core heating at high frequency. 3) please consult characterisation report for more technical details and application advice. 4) operating at 12v vc < 15v will reduce the measuring range. 051011/9 lem industrial www.lem.com lem reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. page 1/3
notes : current transducer hat 200..1500-s isolation characteristics rated voltage 1000 v with iec 61010-1 standards and following conditions - reinforced insulation - over voltage category iii - pollution degree 2 - heterogeneous field v d r.m.s. voltage for ac isolation test, 50 hz, 1 mn 3 kv dcp creepage distance > 11 mm dcl clearance distance > 11 mm cti comparative tracking index (group iiia) 275 051011/9 lem industrial www.lem.com lem reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. page 2/3
3 0 . 5 x 4 0 . 5 7 0 9 0 7 8 1 2 1 2 = = = = 1 4 m o l e x 5 0 4 5 - 0 4 a p o s i t i v e c u r r e n t f l o w 1 6 3 0 . 5 x 4 0 . 5 4 3 2 1 m o l e x 5 0 4 5 - 0 4 a h a t 2 0 0 - s 3 0 . 5 x 4 0 . 5 7 0 9 0 7 8 1 2 1 2 = = = = h a t - s s e r i e s 1 4 p i n s a r r a n g e m e n t : 1 2 3 4 ( + ) ( - ) o u t p u t 0 v f i x a t i o n b y b a s e - p l a t e o r o n b u s b a r w i t h m 4 s c r e w s a l l h o l e s o 4 . 5 m m m o l e x 5 0 4 5 - 0 4 a 9 9 / 0 5 p o s i t i v e c u r r e n t f l o w 1 6 3 0 . 5 x 4 0 . 5 4 3 2 1 m o l e x 5 0 4 5 - 0 4 a h a t 5 0 0 - s t o 1 5 0 0 - s h a t 2 0 0 - s ( u n i t = m m ) 5 12 24 29 38 46 max . 15.5 4 10 30 65 4 mechanical characteristics general tolerance 1 mm transducer fastening by base-plate or on bus bar with m4 screws. all slots ? 4.5 mm connection of secondary molex 5045-04a remarks i s is positive when i p flows in the direction of the arrow. temperature of the primary conductor should not exceed 100c. dimensions hat 200..1500-s (in mm. 1 mm = 0.0394 inch) front view top view 10 051011/9 lem industrial www.lem.com lem reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. page 3/3 pins arrangement 1 2 3 4 (+) ( - ) output 0 v safety this transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. caution, risk of electrical shock when operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). ignoring this warning can lead to injury and/or cause serious damage. this transducer is a built-in device, whose conducting parts must be inaccessible after installation. a protective housing or additional shield could be used. main supply must be able to be disconnected.


▲Up To Search▲   

 
Price & Availability of HAT1000-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X